Tono-Vera® Tonometer
Featuring ActiView™ Positioning System – Now Available!
Truly Effortless & Objective Tonometry with Tono-Vera® Tonometer
Introducing the all-new Reichert® Tono-Vera® Tonometer featuring the advanced, patented ActiView™ Positioning System, your guided view to precise IOP measurements, which quickly guides you to the apex of the cornea. Using gentle rebound tonometer technology and eliminating the need for topical anesthetic, Tono-Vera automatically measures when aligned. Tono-Vera provides more objective and repeatable results giving you confidence in your intraocular pressure (IOP) readings. For nearly two centuries, Reichert continues to advance tonometry, refraction, and dry eye diagnostics through continuous innovation.
-
Details
-
Videos
-
Specs
-
FAQs
-
Brochures
-
Software
-
Related Items
Tono-Vera® Tonometer – Your guided view to precise, automated IOP measurements.
"Tono-Vera® auto-measures, no need to guess or miss the moment." – Allison McGraw, OD, FAAO
A more objective measurement with ActiView™.
The Tono-Vera® Tonometer ActiView™ Positioning System features a full color view of the eye combined with intuitive, interactive alignment prompts to guide the user precisely to the apex of the cornea. When proper alignment is achieved Tono-Vera automatically measures, providing a result in as few as three measurements. Intuitive color-coded rings indicate the reliability of the reading.
All the important information, always on display.
Tono-Vera Tonometer has a comprehensive yet clutter-free user interface.
Tono-Vera Tonometer, innovative and thoughtfully designed.
Lightweight, Ergonomic, and Calibration-free
The perfectly placed operator-facing display and lightweight, symmetrical design allow for comfortable left or right-handed operation. Intuitive button placement provides easy access to all settings and measurement functions. Always ready to measure with no routine calibration required.
Rechargeable, AA, or Both
Tono-Vera is available in two models – Rechargeable or AA Battery. Rechargeable Model means fewer batteries in landfills and a device that is always ready to use. AA Battery Model goes anywhere and allows for a quick and easy battery change with no additional tools required. Rechargeable and AA Battery Packs are interchangeable, providing ultimate flexibility.
A Base for Everything & Everything in its Place
The included multi-purpose Tono-Vera Base is the perfect solution for docking Tono-Vera and charging your Rechargeable Model, while also conveniently storing and dispensing Ocu-Dot® Tonometer Probes.
Ready for the Road
When your patients can’t come to you, bring Tono-Vera to them in the durable, lightweight, and protective carry case.
Comfort and Control
Innovative FlexiSoft™ Forehead Rest has been designed for easy distance control and patient comfort.
Electronic Health Record Ready
Tono-Vera is Bluetooth enabled, allowing for software updates and Electronic Health Record connectivity.
Ocu-Dot® Tonometer Probes
Specially designed for Tono-Vera Tonometers, Ocu-Dot® Tonometer Probes are single-use, individually packaged for fast and easy loading, and come in boxes of 100 count.
Improving eye care through continuous innovation.
At Reichert®, we stand by our products giving Tono-Vera Tonometer a two-year warranty.
Tono-Vera is designed, engineered, and assembled in Buffalo, New York, USA.
Reichert is Technology, Tradition & Trust.
For over 75 years, Reichert has paved the way for continuous advancement in tonometry and glaucoma diagnostics. With the introduction of Tono-Vera, Reichert now offers the most comprehensive line of tonometry solutions.
Reichert is a global innovation leader in tonometry, offering a wide-range of tonometry options including Reichert® 7CR Auto Tonometer with Corneal Compensated IOP (IOPcc), Ocular Response Analyzer® G3 with Corneal Hysteresis +IOPcc, the unique Model 30™ Pneumatonometer with tonography and ocular pulse amplitude, the award-winning Tono-Pen AVIA® with QuickTap® Measurement Mode, and now the advanced Tono-Vera Tonometer with ActiView Positioning System.
*This device may not be cleared for sale in all countries.
Catalog Number:
16306 Tono-Vera® Rechargeable Starter Kit
16305 Tono-Vera® AA Battery Starter Kit
16326 Tono-Vera® Rechargeable Starter Kit - CE Marked Model
16325 Tono-Vera® AA Battery Starter Kit - CE Marked Model
Includes:
• Tono-Vera
• Tono-Vera Carrying Case
• Tono-Vera Charging Base (16306 and 16326)
• Tono-Vera Base (16305 and 16325)
• Tono-Vera Li-Ion Rechargeable Battery Pack (16306 and 16326)
• Tono-Vera AA Battery Pack (16305 and 16325)
• Tono-Vera Training Aid
• Tono-Vera Spare Probe Chamber Kit
• Ocu-Dot® Tonometer Probes - 100 count
• USB-C Charging Cable (16306 and 16326)
• Charging Plug (16306 and 16326)
• Pack of Four AA Batteries (16305 and 16325)
Weight: 4.2 oz. (120.3 g)
Length: 8.4 in. (21.25 cm)
Width: 2.6 in. (6.6 cm)
Thickness: 1.2 in. (3.0 cm)
Measurement Range: 5-60 mmHg (Display range 1-99 mmHg)
Accuracy: ±1.0 mmHg (5-20 mmHg), ±2.0 mmHg (21-60 mmHg)
Power Source: Tono-Vera Li-Ion Rechargeable Battery Pack or Tono-Vera AA Battery Pack
WARNING: Only use Reichert® Ocu-Dot® Tonometer Probes with Tono-Vera® for accurate IOP measurements. Probes from other manufactures will cause inaccurate IOP measurements.
FAQs
What is Tono-Vera® Tonometer?
How does Tono-Vera Tonometer compare to Goldmann Applanation Tonometer (GAT)?
Tono-Vera Tonometer is highly correlated with Goldmann Tonometry. It has met international regulatory standards for tonometer accuracy. The Tono-Vera ActiView Positioning System automatically measures when aligned, providing more objective IOP readings that clinicians can have confidence in.What are the advantages of using a rebound tonometer, such as the Tono-Vera Tonometer?
Rebound tonometry is a method used to measure intraocular pressure (IOP) without the need for anesthetic drops. A small, lightweight probe is gently propelled toward the cornea, making brief contact with the eye and then rebounding back. The device measures the deceleration of the probe during this rebound which correlates with the IOP. There is minimal risk of cross-contamination because of the single-use probes.How is Tono-Vera Tonometer different than other rebound tonometers?
Tono-Vera Tonometer effortlessly delivers fast, repeatable IOP readings with the patented ActiView Positioning System technology, providing guided alignment and automated measurements. Ocu-Dot® Tonometer Probes are engineered for Tono-Vera Tonometers to deliver fast, hygienic, and accurate IOP readings.Who can use the Tono-Vera Tonometer?
Tono-Vera Tonometer’s intuitive interface and ActiView Positioning System reduces operator variability, ensuring consistent results across trained users.What comes in the Tono-Vera Tonometer Starter Kit?
The kit includes the Tono-Vera Tonometer device, docking base, Ocu-Dot Probes, and either AA or rechargeable battery cartridge options.How do I load the probe?
Remove the Ocu-Dot Probe tube cap, insert the probe into the chamber, and rotate until it slides into place.How should I position the Tono-Vera Tonometer when taking a reading?
Hold Tono-Vera Tonometer so the Ocu-Dot Probe and Canthus Marks are perpendicular to the eye. Adjust the Flexi-Soft™ Forehead Rest to assist with positioning by rotating the Flexi-Soft Forehead Rest Adjustment Wheel. Using the ActiView Positioning System, align the probe to the eye such that the probe angle is ±15º from level and the probe tip is approximately 6 mm (±1.5mm) from corneal apex. Tono-Vera Tonometer will automatically measure when properly aligned.Tono-Vera can be rotated a full 360º around the axis of the Ocu-Dot Probe, as long as the probe is kept parallel to the ground, within the ±15º probe angle range.
Can I use Tono-Vera Tonometer to measure IOP in a supine position?
Since Tono-Vera Tonometer can be rotated a full 360º around the axis of the Ocu-Dot Probe (as long as the probe is kept parallel to the ground, within the ±15º probe angle range) reclined or recumbent patients can be measured by positioning their head to the side.How does Tono-Vera Tonometer’s ActiView Positioning System work?
The Tono-Vera Tonometer ActiView Positioning System guides the user to the correct alignment using visual indicators. When proper distance of 6mm (±1.5mm), centration, and probe angle (±15º) are achieved, the device automatically takes the measurement.What do the result colors mean?
• Green Ring: High-confidence final IOP result
• Yellow Ring: Low-confidence final IOP result
• Orange Ring: No result; retake measurement.
How many readings are needed?
Tono-Vera Tonometer can take 3 or 6 readings depending on the selected mode.Can measurements be taken manually with Tono-Vera Tonometer?
Yes, Tono-Vera Tonometer has 2 measurement modes, manual and automatic. We recommend using automatic mode.Are Ocu-Dot Tonometer Probes interchangeable with other tonometer probes?
No, Reichert’s Tono-Vera Tonometer was cleared to be used with Ocu-Dot Tonometer Probes only.Can I connect the Tono-Vera Tonometer to my EMR system?
Yes, Tono-Vera Tonometer features built in Bluetooth data transfer, allowing you to send data with the touch of a button. Pair Tono-Vera Tonometer with ReichertSync® and the software will automatically connect with the device anytime the Bluetooth is enabled.Where can I buy replacement probes or accessories?
Accessories and consumables are available from your authorized Reichert distributor as well as the Reichert Online Store in the USA.
Ocu-Dot® Tonometer Probes
Box of 100, Single-Use
For Tono-Vera® Tonometers
Come in individual vials, easy to install, convenient to dispose, perfectly paired with the Tono-Vera Base.

Tono-Vera® Vet
Veterinary Handheld Tonometer with ActiView™ Positioning System
The right measurement, right away. Confidence in a patented, single, automated IOP measurement you can see.